NSN 5925-01-149-9299 Parts of Circuit Breaker
In the event that you are looking for top quality NSN parts under the NSN 5925-01-149-9299, like AM2-Z159-8, AM2R-Z159-8, APL11-4301-11 or others, our team is your finest option. The people at our group can boast of an ISO 9001:2015 accreditation and a FAA AC-0056B certification from the official Federal Aviation Administration group (FAA). Not just that, as a result of our regard to due diligence and quick cutoff times, our customers can depend on us to quickly stock, obtain, deliver and fulfill on whatever parts they are searching for.
For whatever aircraft part of 5925-01-149-9299 you require, you can trust in the professional and expert group at One Click Aviation to have first class determinations for them. Reach us today and see how rapidly we can support you! Our organization offers such advantages like same-day and following day delivery, 100% quality affirmation, every minute of every day client assistance, serious statement in the aeronautics secondary selling and more. Contact us today and see how quickly we can fulfill you Instant RFQ.
Alternative NSN: 5925-01-149-9299 |
Item Name: Circuit Breaker |
Federal Supply Class (FSC): 5925 Circuit Breakers |
NIIN: 011499299 |
NCB Code: USA (01) |
Manufacturers: Eaton Corporation , Sensata Technologies Inc |
Part No | Manufacturer | Item Name | QTY | RFQ |
---|---|---|---|---|
AM2-Z159-8 | eaton corporation | circuit breaker | Avl | RFQ |
AM2R-Z159-8 | eaton corporation | circuit breaker | Avl | RFQ |
APL11-4301-11 | sensata technologies inc | circuit breaker | Avl | RFQ |
Characteristics Data of NSN 5925011499299
MRC | Criteria | Characteristic |
---|---|---|
AAJE | THREAD PITCH DIAMETERS | +0.1177/+0.1214 INCHES |
AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
ADAQ | BODY LENGTH | 2.480 INCHES MINIMUM AND 2.520 INCHES MAXIMUM |
ADAT | BODY WIDTH | 1.480 INCHES MINIMUM AND 1.520 INCHES MAXIMUM |
ADTV | CASE MATERIAL | PLASTIC |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.928 INCHES MINIMUM AND 1.948 INCHES MAXIMUM |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.052 INCHES MINIMUM AND 2.072 INCHES MAXIMUM |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.740 INCHES MINIMUM AND 0.760 INCHES MAXIMUM |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AJEC | BOSS HEIGHT | 0.130 INCHES MINIMUM AND 0.150 INCHES MAXIMUM |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 3.590 INCHES MAXIMUM |
AKPX | POLE QUANTITY | 2 |
APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
BBRJ | SPECIAL HANDLING FEATURE | MAGNETIC |
CBBL | FEATURES PROVIDED | HIGH INRUSH PROTECTION |
CMLP | THREAD QUANTITY PER INCH | 32 |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 50.0 AMPERES DC FIRST LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 35.0 DC SECOND LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 65.0 DC FIRST LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000.0 DC ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS SECOND LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY FIRST LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 115.0 ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 2 TOGGLE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT EACH POLE |
CPRY | EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE AND TWO LINKED |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.150 MINIMUM AT 200 PCT FIRST LOCATION AND 1.500 MAXIMUM AT 200 PCT FIRST LOCATION |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS RESISTANT AND MOISTURE RESISTANT |
FEAT | SPECIAL FEATURES | HIGH INRUSH POLE ONE ONLY |
PKWT | UNPACKAGED UNIT WEIGHT | 6.438 POUNDS |
TEST | TEST DATA DOCUMENT | 80063-SM-A-838525 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING |
THSD | THREAD SERIES DESIGNATOR | UNC |
TTQY | TERMINAL TYPE AND QUANTITY | 4 THREADED STUD |
5925-01-149-9299, 5925011499299 Search Related NSN Catalog
Warrantied inventory at competitive prices
Search the world's largest inventory of electronic components by manufacturer, category or part number
We sell only warrantied and traceable parts
All inventory ready to ship from our sellers